RTV Insulator Anti Flashover coating

The electrical power system Anti Flashover the coating with the single component normal temperature solidification silicon rubber is the RTV insulator Anti Flashover the coating is our company in domestic first develops in 1990 the beginning of ages successfully. The silicon valley brand sign RTV insulator anti flashover the coating to pass, the provincial level appraisal, The nation anti Flashover the expert group to appraise,ISO9001 International quality system authentication and sign DL/T 627 complete patterns experiments; its performance index has achieved the international advanced level . In metallurgy, cement, chemical industry, mine and salt mist and so on, each kind of contamination environment application, and in 500kV system big area use, displays finely anti flashover performance, since has drifted net moves for ten years, does not have dirt to flashover accident, has guaranteed the electrical network movement security and is reliable.

<!--[if !supportLists]-->1. <!--[endif]--> The characteristic and the performance

<!--[if !supportLists]-->·           <!--[endif]-->The fine hydrophobic character and fast, is balanced the hydrophobic migratory nature which, continues;

<!--[if !supportLists]-->·           <!--[endif]-->The anti-flashover the voltage to be high, The anti- electric arc, bears leaks the mark, the electrical insulating property is fine;

<!--[if !supportLists]-->·           <!--[endif]-->The high module, high strength, excels in the adhesion, High corrosion tolerance, Satisfied condition overhaul request;

<!--[if !supportLists]-->·           <!--[endif]-->Bears the ozone, bears the ultraviolet ray, bears the environment aging, Does not get up the skin, Does not crack, The effective running time is long;

<!--[if !supportLists]-->·           <!--[endif]-->Single component normal temperature solidification, In -20 ℃ still might construct, Easy to operate, In the normal maintenance time exempts sweeps clear, The efficiency is high.

<!--[if !supportLists]-->2. <!--[endif]--> Main qualification

This equates use department sign DL/T627 "electrical power system Anti flashover Coating with Normal temperature Solidification Silica gel", And has drawn up higher enterprise standard QB/SV09 "The RTV Insulator Anti flashover Coating" and QB/SV08 "RTV Coating Construct control Standard" comes the standard product the production and the construction application.

3.  Range of application

This is suitable for rated voltage 0~750kV,Ambient temperature -50 ℃ ~200 ℃,Under the contamination condition moves junction, direct current system, Mainly uses in the power supply bureau transformer substation, the power plant booster station and loses the distribution line insulator and the chemical industry, the steel and iron, the electric railway, the mine pit and all easy contamination, the easy mist, to pour water on the moist electrical equipment, Enhances the equipment outside to insulate the rank, prevents the flashover accident the occurrence.

<!--[if !supportLists]-->4. <!--[endif]--> Operation Guide

Before the construction carries on the convention to the porcelain insulator or the glass surface to sweep clear, Decontamination and degreasing, fat processing, The maintenance surface clean is clean. May use to spurt spreads or brushes spreads the way to carry on the construction, Coating thickness should regard the scene contamination degree but to decide, Thickness 0.3 ~ 0.5mm, The coating should leak proof spread, not dribble, does not hang the silk. When the coating uncaps the use, If has not used up, Should cover securely immediately, The airtight preservation next time again will use.

5Packages and Storage

This product packing in airtight metal container, when storing and transportation should maintain dry and ventilates, Prevented all day exposes to the sun, the rain drenches. The storage time is 1 year, Duplicate surpassed the storage time after to examine qualified still may use.

 

RTV The insulator antifouling Flashover the coating technical specification data sheet

Item

DL/T 627 Standard

Technical Property

 Test Value

Test Method

Outward appearance

Does not have the obvious mechanical impurity, does not have the cotton wool shape precipitation, after the solidification smooth smoothly does not have the air bubble

White (red, ash, is transparent) the color mobile liquid, the coating smoothly does not have the air bubble

GB 1721-79

Solid content   %

≮22

55

GB 1725-89

Viscosity       s

15~60

30

GB 1723-93

Surface  resistivity

Ω·m

≮1×1012

1.8×1016

GB 1410-78

Volume resistivity Ω·m

≮1×1014

1.5×1014

Relative permittivity dielectric lose tangent value

≯3.0

2.35

GB 1409-78

≯0.3%

3.0×10-3

Breakdown field value  MV/m

≮15

25.6

GB 1408-78

Arc resistance   s

≮180

190

GB 1411-78

Resistance to track

and erosion TMA

≥2.5

1A 2.5

GB 6553-86

Adhesion ability (drawing the cycle method  )

No less 2 level

1~2 level

GB 1720-89

Abrasion resistance   g                 

≯0.05

qualified;

GB 1768-89

Rate of water absorption    %

≯0.25

0.16

GB 1738-89

Hydrophobicity

Hydrophobic angle >90°

111.6°

DL/T627-1997

Corrosion proof

Under the acid, the alkali, the salt and the transformer oil function do not have the corrugation, falls off, bubbles, changes color and so on

The experiment does not have the corrugation to fall off bubbles changes color the phenomenon

GB 1739-89

GB 1763-89

The labor frequency arc-over voltage (dryly flashover , wet flashover )   KV

Has the coating insulator not to have the coating insulator not to have relatively to reduce

Have coat  90.3 ,

no coat  89.5

GB 775-87

Have coat   52.0 ,

no coat  49.6

Flashover resistance

U1(have paint coat)/U2

(no paint coat )>1.5

2.34(average)

GB 4585.1-84

The environment aging performance resistance

The coating should not be  cracked under the natural condition, the pulverization, the skin and falls off

After the sample moves for 10 years the coating to be complete, has the good hydrophobic character

GB11206-89

Artificial accelerate ageing

Coating after 1000h artificial accelerated ageing test, is  intermediate at least

1000h the salt-fog test does not have has flowed the severance according to GB/T1766 evaluates is 1 level

GB1865-80

Heat resistant denaturation experiment (adhesive force)

Bears 5 times of temperature cycles , the experiment but does not damage

Translation failed! please try again.

DL/T627-1997

Vulcanizing  time

Surface  dry up ≯30 min

Surface dry up  25 min

GB 6753.2-86

Full dry up  ≯7days

Full dry up  72h

 

 

svchem65@yahoo.com.cn
close

This entry hasn't been re-blogged:

Re-Blogged By Re-Blogged At
Tags:
rtv insulator anti flashover coating

Anonymous
Post a Comment
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the tree to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the pencil to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Anonymous
Post a Comment
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the lamp to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Rainer
2,200

tang tian

Ask me a question
*
*
*
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the pants to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase: