Why All the Crap In Front?

By
Home Inspector with Square One Home Inspection

Have you given any thought to your electrical panel lately? Probably not in most cases. Do you know where it is located inside your home? Most of us do know that, it is behind that big pile of boxes in the basement, right? Unfortunately, this is the case many times during one of my home inspections. I am not a moving company, if items are blocked, I cannot inspect them.

In regards to the electrical panel in your home, there are certain clearances that you want to be observing. These clearances have been established for a number of reasons, so it is important that they are allowed for. The biggest reason for these clearances is safety of the home occupants. If, for whatever reason, the power needs to shut of immediately, it can be very hard to do with a pile of boxes in the way.

By maintaining the proper clearances in front of your homes' electrical panel, you can access it much easier when needed, such as when a breaker trips. If you need to have repairs done, it will also be appreciated by the electrician that will be performing the work. He's not a moving guy either.

The following clearances should be maintained around the electrical panel in your home. The minimum head room should be 6 ½'. You do not want to have to be all crouched down to access the panel, as you could stumble and fall into the panel, resulting in severe injury, or worse. In front of the panel, we are going to want to see 3' of clear open space. This will allow someone to stand directly in front of the electrical panel, and not have to lean over anything to perform work or switch the breakers in the electrical panel. Also, around the sides of the panel there should be 30" of clear, free space. This should eliminate anything falling into the panel if the cover is off while performing any electrical work on the panel itself.

Beaver Dam home inspector explains electrical panel clearances

Remember, for your own personal safety, please observe the above stated clearances in front of your homes' electrical panel. Do not store items in front of the panel, as emergency access will be hindered. If you are storing items in front of your electrical panel, please move them for your families' safety. If there are problems in your electrical panel, you may not notice them as quickly if you have it buried behind a wall of boxes.

The best practice is to keep your electrical panel unobstructed and have a clear path to access it in case of emergency. Go check your panel out right now. Is it easily accessible?

 

©Square One Home Inspection 2009

Posted by

 

Ian A Niquette

 www.squareonehomeinspection.com

 Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections and Radon testing available.

 

 

close

This entry hasn't been re-blogged:

Re-Blogged By Re-Blogged At
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the umbrella to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Topic:
ActiveRain Community
Location:
Wisconsin
Groups:
Almost Anything Goes
Home Inspector's Corner
MADISON WISCONSIN REALTORS
Realtors®
Wisconsin Active Rainers
Tags:
home inspection
safety

Comments 7 New Comment

Anonymous
Post a Comment
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the clock to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Rainmaker
1,654,445
William Feela
Realtor, Whispering Pines Realty 651-674-5999 No.
WHISPERING PINES REALTY

Ian...very good point.  It's like when they put the box in  a very small closet

August 11, 2009 07:33 AM
Rainmaker
351,418
Damon Gettier
Broker/Owner ABRM, GRI, CDPE
Damon Gettier & Associates, REALTORS- Roanoke Va Short Sale Expert

Ian, thanks for visiting my blog.  This blog post is a good point.  Would you mind if I printed it for use in my Seller Packets?

August 12, 2009 08:54 PM
Rainer
47,895
Ian Niquette
Square One Home Inspection

Damon, glad yo ufound it informative. Feel free to use it, it might come in handy for you.

August 13, 2009 06:28 AM
Rainmaker
58,070
Dana Bostick
True Professionals, Inc.

Many clients and homeowners do not "get" it when I describe these requirements.  The electrical panel is something most have NEVER had to access.

I make it much clearer by telling them to imagine that an old style phone booth has to fit in front of the panel. They can "see" that picture easily.  I can see the "light come on" when I describe it this way.

August 15, 2009 09:21 AM
Anonymous #7
Anonymous
Anonymous

I like Dana's comment (#6) about how he describes the space required.

Inadequate clearance in front of electric panel

September 03, 2009 03:48 AM
Anonymous
Post a Comment
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the leaf to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase:

Rainer
47,895

Ian Niquette

Ask me a question
*
*
*
Spam prevention

Accessibility option: listen to a question and answer it!

To submit the form,
drag the robot to the circle on the side.

Type below the answer to what you hear. Numbers or words, lowercase: